ZMJ60V Density Monitor

ZMJ60V Density Monitors are used to monitor the density of SF6 gas in sealed tanks, and can be widely used in medium voltage switchgear, RMU. It’s suitable for outdoor harsh conditions. It can provide multiple solutions to support new substations and the renovation and upgrading of existing substations. The electrical maintenance personnel can make SF6 gas density monitor calibration or gas filling without disassembling SF6 density monitor.
zmj60v-density-monitor
  • zmj60v-density-monitor
  • zmj60v-density-monitor-1
Share It :

Application of ZMJ60V Density Monitor


  • Sf6 Gas Insulated RMU

  • Sf6 Gas Insulated Switchgear


Feature of ZMJ60V Density Monitor


  • Compact design, customized installation interface, convenient and reliable.

  • Process connection customizable in accordance with customer’s demands.

  • Up to three sets of switching contacts can be provided according to user’s needs.

  • Without disassembling SF6 density monitor, SF6 gas density monitor can be calibrated or replaced

  • Without disassembling the screws, a person can operate independently, which is convenient.

  • Temperature compensation for higher accuracy

  • It can facilitate on-site personnel to measure micro-water and supplement air for switch

  • Avoid the sealing surface and sealing joint damage caused by the disassembling


Technical Data of ZMJ60V Density Monitor




Case diameter:φ64mm
Case material: Stainless steel
Scale range: 0 to 2bar abs.customizable
Accuracy: ±1.5%FS+20±1℃),±2.5%FS-20℃+60℃(gas phase)
Ambient conditions:-20°C to 60°C, relative humidity95%RH
Degree of protection:IP65
Leakage rate: 1 × 10-9 Pa·m3/s (Helium leakage inspection)
Contact type:  Magnetic snap-action contacts (up to 3 sets, NO or NC)
Process connection:M20×1.5 (customizable)
Maintenance connection: M16×1.5 (customized and additional adapter needed to the calibrator or gas tank)
Installation mode:radial or axial
Insulation resistance: >100MΩ (DC500V)
withstand voltage: 2kV, 50/60Hz, 1min
Contact electrical parameters:Rated Power: 30VA
Rated Power30VA
Max. operating voltage:380V  
Max. current:1A
Weight:0.6kg
Pressure element:Bourdon tubes




Options of ZMJ60V Density Monitor


  • Different measuring ranges

  • Wide temperature range -40°C to +60°C

  • Measuring Medium: SF6, Air, N2, SF6+N2 and other gases

  • Remote transmission function

  • Optional measurement accuracy:±1.0%FS(+20±1℃),±2.5%FS(-20℃~+60℃)(gas phase)


Brands We Cooperate
abb
siemens
schneider
toshiba
hyosung
Pressure Instruments Inquiry
Pictures or documents for technical requirements (optional)
Related Density Meter for Reference
Related News
Understanding the Sulfur Hexafluoride Gas Density Monitor
Working Principle of Sulfur Hexafluoride Gas Density MonitorThe working principle of the sulfur hexafluoride gas density monitor is mainly based on the detection of the degree of gas ionization under ...
Wed 06 2025
Principle and Overview of the SF6 Relay
The Working Principle of the SF6 RelayThe working principle of the sulfur hexafluoride (SF6) gas density relay is primarily based on the relationship between the pressure and density of SF6 gas, along...
Sat 06 2025
Remote Transmission Type Sulfur Hexafluoride Gas Density Monitor: Ensuring Safe Operation of Power Systems
Ensuring the Insulation and Arc-quenching Performance of EquipmentThe density of SF6 gas is a key parameter that determines its insulation and arc-quenching performance. When leakage occurs and the de...
Tue 06 2025
Lanso Instruments INC.
233 W 1st St #210, North Vancouver, Canada
info@lansoinstruments.com
233 W 1st St #210, North Vancouver, Canada
info@lansoinstruments.com