language
Contact Us

DT10 Density Transmitter

DT10 Density Transmitters are used to monitor SF6 gas density in sealed tanks. It can provide multiple solutions to support new substations and the renovation and upgrading of existing substations.
DT10-Density-Transmitter-01
  • DT10-Density-Transmitter-01
  • DT10-Density-Transmitter-02
Share It :

Application of DT10 Density Transmitter


  • SF6 Gas Insulated Swithchgear (GIS)

  • SF6 Insulated Circuit Breaker

  • SF6 Insulated Pole-Mounted Switch

  • SF6 Insulated Transformer

  • SF6 Insulation Current Transformer or Voltage Transformer

  • SF6 Insulated Bus System


Features of DT10 Density Transmitter


  • Suitable for medium or high volatage systems

  • All welded sensor structure, long-term stable sealing performance

  • RS485 bus interface (Modbus RTU)

  • Strong EMC capability


Technical Data of DT10 Density Transmitter


  • Measuring range: 0 ~ 1.0MPa

  • Accuracy of transmitter:

  • Temperature:±1℃

  • Pressure:±0.5%FS.

  • Pressure at 20℃:±1.0%FS.

  • Degree of protection: IP65

  • Ambient Condition: -40℃~ +70℃, Relative humidity ≤95%RH

  • Leakage rate: ≤1 x 10-9Pa·m3/s (Helium leakage inspection)

  • Process connection: M20 x 1.5 (customizable)

  • Electrical connection: M12 x 1 Circular connector 

  • Weight: 0.1kg

 

 

Technical Parameters for Remote Module

Operating voltage: 10~30VDC

Power consumption: <0.5W

Communication mode: RS485

Communication protocol: Modbus RTU

Baud rate: 9600bps

 

EMC tests:

IEC61000-4-2: level 4(15kV)

IEC61000-4-3: Level 3 (10V/m)

IEC61000-4-4: Level 4 (4kV)

IEC61000-4-5: level 3 (1kV /2kV)

IEC61000-4-8: level 5 (100A/m)

IEC61000-4-9: level 5 (1000A/m)

IEC61000-4-10: level 4 Class (30A/m)



Options of DT10 Density Transmitter


Measuring Medium: SF6, Air, N2, SF6 + N2and other gases

 

 Ex.Field-installable_connector.png

Ex.Field-installable connector


Brands We Cooperate
abb
siemens
schneider
toshiba
hyosung
Pressure Instruments Inquiry
Pictures or documents for technical requirements (optional)
Related Density Transmitter for Reference
Related News
SF6 Relay: Accurate Protection, Advantages Revealed
The SF6 relay is mainly used to monitor the density of SF6 gas in sealed containers. It is widely used in high-voltage electrical equipment that utilizes SF6 gas as an insulating medium and is suitabl...
Tue 04 2025
SF6 Gas Density Monitor: The New Darling Ensuring Safety in the Electric Power Industry
With the rapid development of the power industry, the application of SF6 gas is becoming increasingly widespread. However, the leakage of this high-performance insulating gas in electrical equipment i...
Tue 04 2025
How SF6 Gas Density Monitors Help Ensure Safe and Efficient Operation of the Electric Power Industry
Sulfur Hexafluoride (SF6) is a colorless, odorless, non-toxic, non-flammable, and stable gas with excellent electrical insulation and arc extinguishing properties. Its electrical insulation capacity i...
Fri 04 2025
Lanso Instruments INC.
233 W 1st St #210, North Vancouver, Canada
info@lansoinstruments.com
233 W 1st St #210, North Vancouver, Canada
info@lansoinstruments.com