+86-400-820-1296
ZMJ100XDR Density Monitor

SF6 Gas Insulated Switchgear (GIS)
SF6 Insulated Circuit Breaker
SF6 Insulated Pole-Mounted Switch
SF6 Insulated Transformer
SF6 Insulated Current Transformers or Voltage Transformers
SF6 Insulated Bus System
Higher accuracy from reference chamber temperature com- pensation technology.
Suitable for indoor or outdoor installation.
Micro-switch that can switch freely between normally open and normally closed points.
Up to 4 set of contacts, can achieve a variety of options such as double alarm and double lock, more safe and reliable monitoring.
High shock resistance. No need to fill oil, no potential oil leakage.
Normally closed contact will not false alarm due to vibration.
RS485 bus interface, easy to do the system expansion, and to achieve telemetry, remote control functions.
Strong EMC capability.
±1%FS display in full range, higher remote transmission
module accuracy, higher indication and remote data consist- ency accuracy.
More accurate gauge indication values and contact switching values throughout the temperature range.
Technical Parameters for Remote Module
|
Operating voltage |
10~30VDC |
EMC tests |
IEC61000-4-2: Level 4 IEC61000-4-3: Level 3 IEC61000-4-4: Level 4 IEC61000-4-5: Level 4 IEC61000-4-6: Level 3 IEC61000-4-8: Level 5 IEC61000-4-9: Level 5 IEC61000-4-10: Level 5 |
|
Power consumption |
<0.5W |
||
|
Communication mode |
RS485 |
||
|
Communication protocol |
Modbus RTU |
||
|
Baud Rate |
9600bps |
Technical parameters
|
Scale range |
-0.1 ~ 0.9MPa |
|
Accuracy of set point |
@20℃ ±1℃, ±1.0%FS @–40℃ ~ +70℃, ±1.5%FS(gas) |
|
Accuracy of indication |
@20℃ ±1℃, ±1.0%FS @–40℃ ~ +70℃, ±2.0%FS(gas) |
|
Accuracy of transmitter |
Pressure:±0.5%FS Temperature:±1℃ Pressure at 20℃: ±1.0%FS |
|
Data Consistency |
@20℃ ±1℃, ±1.0%FS @–40℃ ~ +70℃, ±1.6%FS(gas) |
|
Degree of Protection |
IP65 |
|
Ambient Condition |
-40℃ ~ +70℃ , relative humidity: ≤ 95%RH |
|
Leakage rate |
≤ 1×10-9 Pa·m3/s (Helium leakage detection) |
|
Process connection |
M20 x 1.5 (customizable) |
|
Installation method |
Radial or Axial |
|
Electrical connection |
Pluggable connector |
|
Insulation property(contact part) |
Insulation resistance: >100MΩ (DC500V) Power frequency withstand voltage: 2kV, 50/60Hz, 1min |
|
Contact type |
Microswitch |
|
Impact rating |
50g |
|
Contact electrical parameters |
10(1.5)A, 250V AC 0.1(0.05)A, 250V DC |
|
Window glass |
Laminated safety glass |
|
Weight |
≈ 1.2kg |
|
Pressure element |
Bellows and Bourdon Tube |
Measuring Medium: SF6, Air, N2, SF6+N2 and other gases

SF6 Gas Density Monitor
SF6 gas density transmitter
SF6 gas valve
SF6 Gas Detection Analyzer Series
Leakage Current Monitoring Series
Transformer Accessories Series