+86-400-820-1296
ZMJ100PR Density Monitor

SF6 Gas Insulated Swithchgear (GIS)
SF6 Insulated Circuit Breaker
SF6 Insulated Pole-Mounted Switch
SF6 Insulated Transformer
SF6 Insulation Current Transformers or Voltage Transformers
SF6 Insulated Bus System
With temperature compensation, ensuring higher measuring accuracy.
Mechatronics design, has precision mechanical struc- ture, and has real-time remote transmission function of electronic signals and on-site dispalyand control.
RS485 bus interface, easy to do the system expan sion, and to achieve telemetry, remote control func tions.
Strong EMC capability.
Suited for different indoor and outdoor installation re- quirements.
AISI 304 hermetically sealed stainless steel case.
The connecting parts are made of AISI 316 stainless steel.
The field display value and output signal are not af- fected by the external environment such as alti tude.
Up to sets of contacts, can achieve a variety ofas dou-ble 4options such alarm and double lock forsafer and more reliable monitoring.
Technical Parameters for Remote Module
|
Operating voltage |
10~30VDC |
EMC tests |
IEC61000-4-2:Level 4 IEC61000-4-3:Level 3 IEC61000-4-4:Level 4 IEC61000-4-5:Level 3 IEC61000-4-6:Level 3 IEC61000-4-8:Level 5 |
|
Power consumption |
<0.5W |
||
|
Communication mode |
RS485 |
||
|
Communication protocol |
Modbus RTU |
||
|
Baud rate |
9600bps |
Technical parameters
|
Case diameter |
100mm |
|
Scale range |
-0.1 ~ 0.9MPa(customizable) |
|
Accuracy |
±1.0%FS(+20±1℃) , ±1.8%FS(-20℃~ +60℃)(gas) |
|
Degree of protection |
IP65 |
|
Ambient condition |
-20℃ ~ +60℃ realative humidity ≤ 95% |
|
Leakage rate |
≤ 1×10-9 Pa·m3/s (Helium leakage inspection) |
|
Process connection |
M20 x 1.5 (customizable) |
|
Installation method |
Radial or axial |
|
Electrical connection |
Pluggable connector, wire diameter 1~ 2.5 mm2 (1.5mm2 recommended) |
|
Insulation property |
Insulation resistance: >100MΩ (DC500V) Power frequency with stand voltage: 2kV, 50/60Hz, 1min |
|
Contact type |
Magnetic snap-action switch (80% Ag, 20% Ni, 10µm gold plated) |
|
Impact rating |
50g(Oil-filled), 30 g(Non-oil-filled) |
|
Contact electrical parameters |
30W/ 50VA,1A. max. 220VDC/ 380V 50/ 60Hz max. |
|
Watch glass |
Laminated safety glass |
|
Weight |
≈ 1.2kg |
|
Pressure element |
Bourdon tube |
Withstand voltage: 2.5kV,50/60 Hz 1min Oil filled or not
Can detect SF6, Air, N2, SF6+N2 and other gases Communication: 4-20mA(Two wire)
Wider temperature range: optional -40℃ ~ +60℃ or -60℃ ~ +60℃
Optional measurement accuracy:±1.6%FS(+20± 1℃) , ±2.4%FS(-20℃~ +60℃)(gas phase)

SF6 Gas Density Monitor
SF6 gas density transmitter
SF6 gas valve
SF6 Gas Detection Analyzer Series
Leakage Current Monitoring Series
Transformer Accessories Series