Leave Your Message
about-us-banner

Products

01

VDA-03 Gas Density Monitor Calibrator - China Suppliers & Factory for SF6 Calibration Solutions

,

The VDA-03 Gas Density Monitor Calibrator is a state-of-the-art, fully automated calibration instrument ideal for testing the performance of Gas Density Monitors used with SF6, SF6/N2 hybrid, and SF6/CF4 hybrid gases. Manufactured in China, this high-end device incorporates advanced embedded microprocessors, ensuring precise calibration and reliability. It features two operational modes: the zero-pressure mode and the working pressure mode. The working pressure calibration mode evaluates the GDM's accuracy from the rated filling pressure down to zero, while the zero pressure mode increments from zero to the rated pressure. As a portable calibration solution, this instrument offers unparalleled convenience for operation, testing, calibration, and maintenance of electrical products. Trusted by various suppliers and industries, the VDA-03 is a must-have for professionals seeking quality and efficiency from a reliable factory source.

,
    shop_iconsAdd ShopCart
    Contact us Download

    ✦ This instrument is engineered for precise, efficient, and field-ready calibration of SF₆ density monitors — featuring dual gas paths, smart proportional valves, and a full suite of connectivity options.
    • The instrument adopts a dual gas path design, supporting two types of gas supply methods: external gas cylinder and internal gas pump.
    • Equipped with a high-performance proportional valve, the calibration rate can be adjusted automatically according to the parameters of the calibrated instrument.
    • Supports calibration of various gas types, including pure SF6, SF6/N2 mixed gas, and SF6/CF4 mixed gas.
    • Output voltage supports 24VDC and 110VDC, and includes the function of measuring contact resistance.
    • Supports both zero pressure and working pressure calibration methods.
    • Equipped with a 7-inch color touch screen for easy observation and operation.
    • Comes with a complete set of transition adapters, enabling field-on-site calibration of most switch density monitors without disassembly.
    • The engineering plastic case is beautiful and durable, offering a high protection level.
    • Equipped with large-capacity memory, allowing calibration data to be stored for a long time.
    • Equipped with a high-speed micro thermal printer to print calibration results immediately after completion.
    • Features a USB interface for easy export of historical data and convenient system upgrades.
    Frequently Asked Questions
    What gas types can this instrument calibrate?
    The instrument supports calibration of pure SF₆, SF₆/N₂ mixed gas, and SF₆/CF₄ mixed gas, making it compatible with a wide range of gas-insulated switchgear density monitoring systems.
    Does the instrument require disassembly of the density monitor during calibration?
    No. The instrument comes with a complete set of transition adapters that allow most models of switch density monitors to be calibrated directly on-site without disassembly, saving significant time and effort.
    What output voltage options are available?
    The instrument supports both 24VDC and 110VDC output voltage options. It also includes a contact resistance measurement function for comprehensive testing capability.
    How is the calibration data stored and exported?
    The instrument is equipped with a large-capacity internal memory for long-term storage of calibration records. Data can be conveniently exported via the built-in USB interface, which also supports system firmware upgrades.
    What calibration pressure methods does the instrument support?
    The instrument supports both zero pressure and working pressure calibration methods, providing flexibility to meet different field calibration requirements and standards.
    Can the instrument print calibration results on-site?
    Yes. The instrument is equipped with a high-speed micro thermal printer that can automatically print calibration results immediately after the calibration process is completed, providing instant documentation in the field.

    Make an free consultant

    Your Name*

    Phone Number

    Country

    Remarks*

    reset