+86-400-820-1296
HM100PR Density Monitors

SF6 Gas Insulated Switchgear (GIS)
SF6 Insulated Circuit Breakers
SF6 Insulated Pole-Mounted Switch
SF6 Insulated Transformers
SF6 Insulated Current Transformers or Voltage Transformers
SF6 Insulated Busbar Systems
They adopt highly reliable protection circuit design, mul- ti-level isolation and filtering technology, thus effectively inhibiting the intrusion of conductive interference.
They adopt the full-body shield design, stainless steel shield- ing shell, shielding junction box and shielding window glass, thus ensuring the ability of anti-electromagnetic radiation interference.
They are able to adopt the optic fiber communication back- stage, thus avoiding data transmission losses from electro- magnetic interference.
The use of high-precision SF6 density algorithm ensures that the background monitoring data coincides with those field instructions.
They are compatible with ordinary SF6 remote products . They do not need other modifications in strong interference occasions.
The temperature compensation device ensures higher meas- urement accuracy.
Technical Parameters for Remote Module
|
Power supply |
24V DC |
Anti-electromagnetic interference |
IEC61000-4-2 IEC61000-4-3 IEC61000-4-4 IEC61000-4-5 IEC61000-4-6 IEC61000-4-8 IEC61000-4-9 IEC61000-4-10 IEC61000-4-12 IEC61000-4-17 IEC61000-4-29 |
level 4/A level 4/A level 4/A level 4/A level 3/A level 5/A level 5/A level 5/A level 4/A level 3/A 0.1s/A |
(8KV/15kV) (30V/m) (4KV) (+/-2Kv) (10V) (100A/m) (1000A/m) (100A/m) (4KV) (10%UN) (40%UT/70%UT) |
|
Power consumption |
< 2W |
||||
|
Communication mode |
RS485 |
||||
|
Protocol |
ModBus RTU |
||||
|
Baud rate |
9600bps |
Technical Parameters
|
Technical Parameters |
|
|
Case diameter |
100mm |
|
Scale range |
-0.1 ~ 0.9MPa (customizable) |
|
Accuracy |
±1.0%FS(+20±1℃) , ±1.8%FS(-20℃~ +60℃)(gas phase) |
|
Degree of protection |
IP65 |
|
Ambient conditions |
-20° C ~ +60° C, relative humidity ≤ 95%RH |
|
Leakage rate |
≤ 1×10-9 Pa·m3/s (Helium leakage inspection) |
|
Process Connection |
M20 × 1.5, (customizable) |
|
Installation method |
Radial or Axial |
|
Electrical connection |
Plug-in connection M20 × 1.5 sealing head cable size: 1.5mm2 recommended, upper limit 2.5mm2 |
|
Contact insulation performance |
Insulation resistance: >100MΩ (DC 500V) Withstand voltage: 2kV, 50/60Hz, 1min |
|
Contact type |
Magnetic snap-action switch 80%Ag, 20%Ni, 10µm Gold plated |
|
Impact rating |
50g (oil-filled), 30g (non-oil-filled) |
|
Contact electrical parameters |
30W/50VA, 1A (upper limit) 220VDC/380V 50/60Hz (upper limit) |
|
Watch glass |
Laminated safety glass |
|
Weight |
≈ 1.2kg |
|
Pressure element |
Bourdon tube |
Oil-filled.
Measuring medium: SF6, Air, N2, SF6 + N2 and other gases.
Wide temperature range :Optional-40℃~ +60℃ or -60° C ~ +60° C.
Optional measurement accuracy:±1.6%FS(+20±1℃) ±2.4%FS(-20℃~ +60℃)(gas phase).

SF6 Gas Density Monitor
SF6 gas density transmitter
SF6 gas valve
SF6 Gas Detection Analyzer Series
Leakage Current Monitoring Series
Transformer Accessories Series