Leave Your Message
about-us-banner
Products
01
Products Categories

HM100PR Density Monitors

HM100PR Density Monitors are used to monitor SF6  gas den- sity in sealed tanks. They are applied to provide alarm signal outputs when the density reaches preset values. Furthermore, it can transmit the real-time SF6  gas density data remotely, to achieve online remote monitoring function.. They are spe- cifically designed for over 500kV EHV grade application field, adapting multi-level protection and full range of shielding measures to ensure the reliable operation of the products.

    shop_iconsAdd ShopCart
    Contact us Download

    1

    SF6 Gas Insulated Switchgear (GIS)
    SF6 Insulated Circuit Breakers
    SF6 Insulated Pole-Mounted Switch
    SF6 Insulated Transformers
    SF6 Insulated Current Transformers or Voltage Transformers
    SF6 Insulated Busbar Systems

    They adopt highly reliable protection circuit design, mul- ti-level isolation and filtering technology, thus effectively inhibiting the intrusion of conductive interference.
    They adopt the full-body shield design, stainless steel shield- ing shell, shielding junction box and shielding window glass, thus ensuring the ability of anti-electromagnetic radiation interference.
    They are able to adopt the optic fiber communication back- stage, thus avoiding data transmission losses from electro- magnetic interference.
    The use of high-precision SF6 density algorithm ensures that the background monitoring data coincides with those field instructions.
    They are compatible with ordinary SF6 remote products . They do not need other modifications in strong interference occasions.
    The temperature compensation device ensures higher meas- urement accuracy.

    Technical Parameters for Remote Module

    Power supply

    24V DC

    Anti-electromagnetic interference

    IEC61000-4-2

    IEC61000-4-3

    IEC61000-4-4

    IEC61000-4-5

    IEC61000-4-6

    IEC61000-4-8

    IEC61000-4-9

    IEC61000-4-10

    IEC61000-4-12

    IEC61000-4-17

    IEC61000-4-29

    level 4/A

    level 4/A

    level 4/A

    level 4/A

    level 3/A

    level 5/A

    level 5/A

    level 5/A

    level 4/A

    level 3/A 0.1s/A

    (8KV/15kV) (30V/m)

    (4KV)

    (+/-2Kv)

    (10V)

    (100A/m)

    (1000A/m)

    (100A/m) (4KV)

    (10%UN)

    (40%UT/70%UT)

    Power consumption

    < 2W

    Communication mode

    RS485

    Protocol

    ModBus RTU

    Baud rate

    9600bps

    Technical Parameters

    Technical Parameters

    Case diameter

    100mm

    Scale range

    -0.1 ~ 0.9MPa (customizable)

    Accuracy

    ±1.0%FS(+20±1℃) ,

    ±1.8%FS(-20℃~ +60℃)(gas phase)

    Degree of protection

    IP65

    Ambient conditions

    -20° C ~ +60° C, relative humidity ≤ 95%RH

    Leakage rate

    ≤ 1×10-9 Pa·m3/s (Helium leakage inspection)

    Process Connection

    M20 × 1.5, (customizable)

    Installation method

    Radial or Axial

    Electrical connection

    Plug-in connection M20 × 1.5 sealing head

    cable size: 1.5mm2  recommended, upper limit 2.5mm2

    Contact insulation performance

    Insulation resistance: >100MΩ (DC 500V)

    Withstand voltage: 2kV, 50/60Hz, 1min

    Contact type

    Magnetic snap-action switch

    80%Ag, 20%Ni, 10µm Gold plated

    Impact rating

    50g (oil-filled), 30g (non-oil-filled)

    Contact electrical parameters

    30W/50VA, 1A (upper limit)

    220VDC/380V 50/60Hz (upper limit)

    Watch glass

    Laminated safety glass

    Weight

    ≈ 1.2kg

    Pressure element

    Bourdon tube

    Oil-filled.
    Measuring medium: SF6, Air, N2, SF6 + N2 and other gases.
    Wide temperature range :Optional-40℃~ +60℃ or -60° C ~ +60° C.
    Optional measurement accuracy:±1.6%FS(+20±1℃) ±2.4%FS(-20℃~ +60℃)(gas phase).