Leave Your Message
about-us-banner

Products

01

China ZMJ80XDR Density Monitor for SF6 Gas - Reliable Suppliers & Factory for High Voltage Systems

ZMJ80XDR Density Monitors are essential devices for monitoring SF₆ gas density in sealed tanks, primarily used in high-voltage systems. These monitors accurately indicate gas density and provide signal outputs when density reaches predefined thresholds. Additionally, they offer the capability to remotely transmit real-time SF₆ gas density data, enabling efficient online monitoring. As a leading manufacturer in China, our factory is dedicated to delivering reliable solutions that cater to the needs of new substations as well as the renovation and upgrading of existing facilities. Partner with trusted suppliers to ensure optimal performance and safety in your electrical systems
    shop_iconsAdd ShopCart
    Contact us Download

    Technical Parameters for Remote Module
    Operating voltage 10~30VDC EMC Tests

    IEC61000-4-2: Level 4

    IEC61000-4-3: Level 3

    IEC61000-4-4: Level 4

    IEC61000-4-5: Level 4

    IEC61000-4-6: Level 3

    IEC61000-4-8: Level 5

    IEC61000-4-9: Level 5

    IEC61000-4-10: Level 5

    Power consumption <0.5W
    Communication mode RS485
    Communication protocol Modbus RTU
    Baud rate 9600bps
    Technical Parameters
    Scale range -0.1 ~ 0.9MPa
    Accuracy of set pressure point

    ±1.0%FS(+20±1℃)

    ±1.6%FS(-30℃~ +60℃)(gas)

    Accuracy of indication

    ±1.0%FS(+20±1℃)

    ±1.8%FS(-20℃~ +60℃)(gas)

    ±2.3%FS(-30℃~ -20℃)(gas)

    Accuracy of transmitter

    Pressure: ±0.5%FS

    Temperature: ±1℃

    Pressure at 20℃: ±1.0%FS

    Degree of protection IP65
    Ambient condition -30℃ ~ +60℃, relative humidity: ≤ 95%RH
    Leakage rate ≤ 1×10⁻⁹ Pa·m³/s (Helium leak detection)
    Process connection M20×1.5, (customizable)
    Installation method Radial or axial
    Electrical connection

    Contact connection: pluggable connector, wire diameter 0.2 ~ 2.5 mm²

    Remote connection: pluggable connector, wire diameter 0.2 ~ 1.5 mm²

    Insulation property (contact part)

    Insulation resistance: >100MΩ (DC500V)

    Withstand voltage: 2kV, 50/60Hz, 1min

    Contact type Microswitch
    Impact rating 50g
    Contact electrical parameters

    10(1.5)A, 250V AC

    0.1(0.05)A, 250V DC

    Window glass Laminated safety glass
    Weight ≈ 1.4kg
    Pressure element Bellow and Bourdon Tube
    Frequently Asked Questions
    Q What is the operating voltage range of the remote module?
    The remote module operates within a voltage range of 10~30VDC, making it compatible with a wide range of industrial power supply systems. Power consumption is kept below 0.5W, ensuring energy-efficient operation.
    Q What communication protocol does the remote module support?
    The remote module communicates via RS485 using the Modbus RTU protocol at a baud rate of 9600bps. This is a widely adopted industrial standard, ensuring seamless integration with PLCs, SCADA systems, and other industrial controllers.
    Q What is the measurement scale range and accuracy of this pressure instrument?
    The instrument covers a scale range of -0.1 ~ 0.9MPa. The accuracy of the set pressure point is ±1.0%FS at +20±1℃ and ±1.6%FS across -30℃ to +60℃ for gas applications. The transmitter achieves a pressure accuracy of ±0.5%FS and a temperature accuracy of ±1℃.
    Q What is the degree of protection and what environmental conditions can this instrument withstand?
    The instrument carries an IP65 protection rating, guarding against dust ingress and water jets. It is designed to operate reliably in ambient temperatures ranging from -30℃ to +60℃ with a relative humidity of up to ≤ 95%RH, making it suitable for demanding outdoor and industrial environments.
    Q What EMC standards does the remote module comply with?
    The remote module has been tested and complies with multiple IEC61000-4 EMC standards, including IEC61000-4-2 (Level 4), IEC61000-4-3 (Level 3), IEC61000-4-4 (Level 4), IEC61000-4-5 (Level 4), IEC61000-4-6 (Level 3), and IEC61000-4-8/9/10 (Level 5). These certifications ensure robust electromagnetic compatibility in industrial settings.
    Q What are the process connection and installation options available?
    The standard process connection is M20×1.5, which is also customizable to meet specific application requirements. Installation can be performed in either radial or axial orientation, providing flexibility for various mounting configurations in the field.

    Make an free consultant

    Your Name*

    Phone Number

    Country

    Remarks*

    reset