ZMJ60XDR Density Monitors are essential devices for monitoring SF6 gas density in sealed tanks, specifically designed for High Voltage systems. As a leading manufacturer from China, our factory produces advanced monitoring solutions that provide accurate readings of gas density. These monitors not only indicate gas density levels but also deliver signal outputs when the density reaches preset thresholds. Additionally, they enable real-time transmission of SF6 gas density data for online remote monitoring, enhancing safety and efficiency in substations. Our products offer versatile solutions for both new substation projects and the renovation of existing infrastructure, making us a trusted choice among suppliers in the industry
    shop_iconsAdd ShopCart
    Contact us Download

    Technical Parameters for Remote Module

    Operating voltage 10~30VDC EMC tests

    IEC61000-4-2: Level 4

    IEC61000-4-3: Level 3

    IEC61000-4-4: Level 4

    IEC61000-4-5: Level 4

    IEC61000-4-6: Level 3

    IEC61000-4-8: Level 5

    IEC61000-4-9: Level 5

    IEC61000-4-10: Level 5

    Power consumption <0.5W
    Communication mode RS485
    Communication protocol Modbus RTU
    Baud rate 9600bps

    Technical Parameters

    Technical Parameters Overview
    Scale range -0.1 ~ 0.9MPa
    Accuracy of set pressure point ±10 kPa @ –30 ~ +60 ° C(gas)
    Accuracy of indication ±10 kPa @ –30 ~ +60 ° C(gas)
    Accuracy of transmitter

    Pressure: ±0.5%FS

    Temperature: ±1℃

    Pressure at 20℃: ±1.0%FS

    Degree of protection IP65
    Ambient condition -30℃ ~ +60℃ , relative humidity: ≤ 95%RH
    Leakage rate ≤ 1×10-9 Pa-m3/s (Helium leak inspection)
    Process connection M20 x 1.5 (customizable)
    Installation method Radial or Axial
    Electrical connection Pluggable connector, wire diameter 0.2~2.5 mm2
    Insulation property (contact part)

    Insulation resistance: >100MΩ (DC500V)

    Withstand voltage: 2kV, 50/60Hz, 1min

    Contact type Microswitch
    Impact rating 50g
    Contact electrical parameters

    10(1.5)A, 250V AC

    0.1(0.05)A, 250V DC

    Watch glass Laminated safety glass
    Weight ≈ 1.2kg
    Pressure element Bellow

    Frequently Asked Questions (FAQ)

    What are the power and communication specifications of the remote module?

    The remote module operates on a voltage range of 10~30VDC with a low power consumption of less than 0.5W. It uses RS485 communication mode, supports the Modbus RTU protocol, and operates at a baud rate of 9600bps.

    What is the environmental protection and temperature range for this device?

    The device features an IP65 degree of protection, making it highly dust-proof and water-resistant. It is designed to operate in ambient temperatures from -30℃ to +60℃, with a relative humidity level of up to 95%RH.

    What is the measurement accuracy of the transmitter?

    The transmitter measures pressure with an accuracy of ±0.5%FS, temperature with an accuracy of ±1℃, and pressure specifically at 20℃ with an accuracy of ±1.0%FS.

    What kind of process and electrical connections are supported?

    The standard process connection is M20 x 1.5 (which can be customized to fit specific needs). The electrical connection uses a pluggable connector compatible with wire diameters ranging from 0.2 to 2.5 mm².

    What are the insulation properties of the contact part?

    The contact part offers an insulation resistance of greater than 100MΩ (at DC500V) and a withstand voltage of 2kV at 50/60Hz for 1 minute.

    What is the leakage rate and impact rating of this device?

    The device has a leakage rate of ≤ 1×10-9 Pa-m3/s verified by Helium leak inspection and features an impact rating of 50g.