China DT10 Density Transmitter for SF6 Gas Monitoring - Reliable Suppliers & Factory Solutions for Substations
Technical Parameters
| Measuring Range | 0 ~ 1.0 MPa |
| Accuracy of Transmitter |
Temperature: ±1℃ Pressure: ±0.5%FS Pressure at 20℃: ±1.0%FS |
| Degree of Protection | IP65 |
| Ambient Condition | -40℃ ~ +70℃, Relative Humidity ≤ 95%RH |
| Leakage Rate | ≤ 1 × 10-9 Pa·m³/s (Helium leakage inspection) |
| Process Connection | M20 x 1.5 (customizable) |
| Electrical Connection | M12 x 1 Circular connector |
| Weight | 0.1 kg |
Technical Parameters for Remote Module
Power & Communication
| Operating Voltage | 10 ~ 30VDC |
| Power Consumption | < 0.5W |
| Communication Mode | RS485 |
| Communication Protocol | Modbus RTU |
| Baud Rate | 9600 bps |
EMC Immunity Standards
IEC61000-4-2 Level 4 (15kV)
IEC61000-4-3 Level 3 (10V/m)
IEC61000-4-4 Level 4 (4kV)
IEC61000-4-5 Level 3 (1kV / 2kV)
IEC61000-4-8 Level 5 (100A/m)
IEC61000-4-9 Level 5 (1000A/m)
IEC61000-4-10 Level 4 Class (30A/m)
Frequently Asked Questions
Q:
What is the measuring range and accuracy of this pressure transmitter?
The instrument provides a pressure measuring range of 0 to 1.0 MPa. It delivers a pressure measurement accuracy of ±0.5%FS (and ±1.0%FS at 20℃) alongside a temperature accuracy of ±1℃.
Q:
What interfaces and protocols are supported by the remote module?
The remote module utilizes an RS485 communication interface operating with the Modbus RTU protocol at a factory baud rate of 9600 bps.
Q:
Can the process connection be customized?
Yes. The standard mechanical process interface is M20 x 1.5, but custom process connection options are available upon request to fit specific installation requirements.
Q:
What are the environmental limits and ingress protection level?
The unit is rated at IP65 protection grade, making it suitable for demanding conditions. It operates reliably within an ambient temperature range from -40℃ to +70℃ and relative humidity levels up to 95% RH.
Q:
What is the power consumption and supply voltage of the module?
The remote module is engineered for energy-efficient operation with an operating voltage of 10 to 30 VDC and a low total power consumption of less than 0.5W.
Q:
What leakage testing standards does the device undergo?
The unit passes stringent helium leakage testing ensuring a tight seal with a maximum leakage rate not exceeding 1 × 10⁻⁹ Pa·m³/s.
SF6 Gas Density Monitor