语言切换
Product material: PU cover material inside pages (80-120 - g) i mport writing pad directly to your door free | | order free design | | free proofing | | free door-to-doordelivery (limit of shenzh en, the other parts adopt way of logistics, logistics cost paid by us)
Type :
All
Gas Density Monitor Gas Density Switch Gas Density Transmitter Pressure Gauge Precision Gauge Differential Pressure Gauge Pressure Transmitter Microwater Dector Instrument & System Valve Diaphragm Accessory
Usage:
All
General Power Food & Beverage Chemical Processing
Accuracy Class:
All
<0.5% 1.0% 1.5% 2.0% 2.5% 3.0% 5.0% 2PPM N/A
Communication:
All
None Electrical RS485 Fibre-Optic Wifi GPRS
  • 市场价: 0 售价: 0
    Measuring range (Low voltage):-100 to 100KPaMeasuring range (Medium voltage): 0 to 25 MPaMeasuring range (High voltage): 0 to 100 MPaDigital accuracy: Class 0.2 or 0.1Temperature accuracy: Class 0.1Dial diameter: 100mmAcquisition speed: 1~10 second/timeWorking temperature: -10 °C to 50 °CCommunication conditions: RS485Power supply: 3 AA batteries, or USB cableBattery operating time: 3600 hours of continuous operation (replaceable battery)Ambient temperature: -20°C to 60°CInterface: M20*1.5, G1/4 according to customer requirements
  • 市场价: 0 售价: 0
    Nominal size 100, 160mmAccuracy class 1.0 Scale ranges 0 ... 0.6 to 0 ... 1,600 bar
or all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitation Steady: Full scale value Fluctuating: 0.9 x full scale value Short time: 1.3 x full scale value Permissible temperature Ambient:  -20 ... +60 °C for gauges without liquid filling and gauges with silicone oil filling Medium:  +200 °C maximum without liquid filling           +100 °C maximum with liquid filling Ingress protection IP 54 per EN 60529 / IEC 60529 Switch contacts Magnetic snap-action contact ■ No control unit and no power supply required■ Direct switching up to 250 V, 1 A
■ Up to 4 switch contacts per measuring instrument Ind...
  • 市场价: 0 售价: 0
    Standard executive: GB/T1226-2001Diameter: 100mm, 1500mmAccuracy: 1.5% (1% available)Measuring range: -0.1MPa to 100MPaDegree of Protection: IP55Ambient temperature: -40 °C to 70 °C,                                       Maximum +200 °C                                      Heat-proof type maximun +300 °CProcess Connection: M20 (M20*1.5), others see tableCase: 08F with black plastic coatSocket: YTF Corrosion-proof pressure gauge is SUS304 original color; YA, YR is 45# Carbonsteel, with black plastic coatBourdon tube: stainless steel argon-arc weldingIntemals: stainless steelJunk ...
  • 市场价: 0 售价: 0
    Design Per US Standard ASME B 40.1Nominal size            4 ½"Accuracy classGrade 2A per ASME B 40.1(corresponds to indication accuracy 0.5 %)Scale ranges 0 ... 0.6 bar to 0 ... 1000 bar (0 ... 10 psi to 0 ... 15000 psi) or all other equivalent vacuum or combined pressure and vacuum rangesPressure limitationSteady: full scale valueFluctuating: 0.9 x full scale valueShort time: 1.3 x full scale valueOperating temperatureAmbient: -40 ... +65 °C without liquid filling-20 ... +65 °C gauges with glycerine fillingMedium: +100 °C maximum1) Temperature effectWhen the temperature of the measuring system deviates from the reference temperature (+20 °C):max. ±0.4 %/10 K of full scale valueIng...
  • 市场价: 0 售价: 0
    DesignEN 837-3 Nominal size 63, 100, 160mm Accuracy class1.6 Scale rangesNS 63: 0 ... 40 mbar to 0 ... 600 mbarNS 100: 0 ... 16 mbar to 0 ... 600 mbarNS 160: 0 ... 2.5 mbar to 0 ... 600 mbaror all other equivalent vacuum or combined pressure and vacuum ranges Pressure limitationSteady: Full scale valueFluctuating: 0.9 x full scale value Permissible temperatureAmbient: -20 … +60 °CMedium: +100 °C maximum Temperature effectWhen the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.6 %/10 K of full scale value Ingress protection per IEC/EN 60529IP54 (without liquid filling)
  • 市场价: 0 售价: 0
    1.Nominal size: 80 mm2.Accuracy:± 3 % full scale ascending3.Scale ranges:0 ~ 400 mbar to 0 ~10 bar 4.Max. working pressure (static pressure) :Optionally 100, 250 or 400 bar5.Overpressure safety:Either side to maximum working pressure6.Operating temperature:   Ambient:0 ~ +60 °C   Medium :+100 °C maximum7.Ingress protection:lP 54 (EN 60 529 / lEC 529)8.Pressure chamber with connections (exposed to pressure medium) :Stainless steel 1.4571, 2 x G 1⁄4 female, entry on the right and left, in-line (EN 837-1 / 7.3)9.Pressure element(exposed to pressure medium) :Compression spring, stainless steel 1.4310 10.Magnetic piston(exposed to pressure medium) : Piston: stainless steel 1.4571, magnet: hard ferrite
  • 市场价: 100 售价: 100
    Lower mount process connections, highly corrosion-resistant all-metal construction, measuring cell secured against unauthorised intervention, process connection location adjustable to mounting conditions, Nominal size in mm 100, 160 Accuracy class 1.6  Scale ranges 0 ... 1.6 kPa to 0 ... 2.5 MPa Scale range 0 ... 1.6 kPa: Scale length approx. 180 ∢ ° or all other equivalent vacuum or combined pressure and vacuum ranges  Pressure limitation Steady: full scale value Fluctuating: 0.9 x full scale value  Permissible temperature Ambient Temperature: -20 ~ +60 °C unfilled                    -40 ~ +60 °C with silicone oil filling        ...
  • 市场价: 0 售价: 0
    Differential pressure gauge For the process industry, high overload safety up to 4、10、25 or 40 MPa Applications·       For measuring locations with a high differential pressure overload and/or high working pressures (static pressures), also in aggressive ambience.·       For gaseous, liquid, particulates-containing, viscous and aggressive media·       Monitoring and control of pumps·       Filter monitoring·       Level measurement in closed tanks Special Features·       Differential pressure measuring ranges from 0 … 60 mbar·       High working pressure (static pressure) and high overload safety up to ...
  • 市场价: 0 售价: 0
    Measuring range: -0.1~250MPaDigital accuracy: Class 0.25 (Class 0.1 if required)Mechanical accuracy: Class 1.0Acquisition speed: 1~60 second/timeCommunication conditions (GPRS): Any GPRS signal environmentCommunication Conditions (LORA): 10kmCommunication conditions (NB): Any NB signal environmentBattery Operating Time (GPRS): 4 years of continuous operation(replaceable battery)Battery Operating Time (LORA): 5 years of continuous operation(replaceable battery)Battery Operating Time (NB): 4 years of continuous operation(replaceable battery)Ambient temperature: -40 °C to 60 °CInterface: according to customer requirementsIntrinsically Safe: Exia II CT6
online shop
Address – Canada:
ADD: 106-828 Harbourside Drive        
          North Vancouver, British Columbia,
          V7P 0A3     
TEL: 1-604-987-3882
FAX:1-604-987-0228
Email: info@lansoinstruments.com
邮编:330520
Address – China:
ADD:50 Lane 3679, Jindu Road, Xinzhuang
          Industrial Zone,
Shanghai, China
TEL:    86-21-54420482
FAX: 86-21-54421043
Email:info@lanso.com.cn
邮编:330520
Copyright © 2018 Lanso Instruments LLC
犀牛云提供企业云服务
Online Inquiries
customer feedback We will promptly reply to your message your message
  • 申请人姓名:
  • *
  • 手机:
  • E-mail:
  • *
  • YOUR FEEDBACK
  • *